Sensor Indicator Panel Combo Unit
Sensor Indicator Panel Combo Unit

Zone Indicator Panel

DOWNLOADS:
BROCHUREMANUALSSPEC SHEETS

Sensor Indicator Panel Combo Unit Specs

FilenameSizeType
ape_sp_snsr_vlv_combo_unit_nfpa0.43MBPDF
ape_sp_snsr_vlv_combo_unit_csa0.46MBPDF
ape_as_sp0.72MBPDF

Model Numbers for NFPA:

 

ZIL-PX


Available Gauges:

V-X-GAUGE-100

V-X-GAUGE-300

V-X-GAUGE-VAC

 

The Letter “L” Defines the Language

U = English (NFPA)

S = Spanish

 

Replace “X” with the Valve Size Required:

1/2" = 05

3/4" = 07

1" = 10

1-1/4" = 12

1-1/2" = 15

2" = 20 F

 

A2X-AVC-ELBOW

1/8 NPT street elbow, used between sensor DISS fittings and shut-off is included, but not attached.


NOTE:

Terminal strips are provided and installed, DISS demand checks and sensors are provided with alarm.

The 1-½" zone shut-off will require an empty space above.

Example: A box with ½", ¾" and 1-½" will require a 4 hole box not a 3 hole box.


The 2" zone shut-off will be assembled in a 6-½" deep box and shall accommodate a maximum of up to 5 gases. The 2" zone shut-off shall be positioned on the bottom of the assembly. Refer to 2" zone indicator panel drawing above. The height measurements of the 6-½" zone shut-off box are the same as the 3-7/8" zone shut-off box. When comparing height measurements, consider the gap above the 2" zone shut-off.

Example: A box with 2", ¾" and a ½" would be in a 3 gang 6-½" box, which would be the same height as the 4 gang 3-7/8" box

 


 

Model Numbers for CSA:

 

ZIL-PX


Available Gauges:

V-X-GAUGE-100

V-X-GAUGE-300

V-X-GAUGE-VAC

 

The Letter “L” Defines the Language

E = English (CSA/ISO)

F = French (CSA/ISO)

 

Replace “X” with the Valve Size Required:

1/2" = 05

3/4" = 07

1" = 10

1-1/4" = 12

1-1/2" = 15

2" = 20 F

2-½" = 25

3" = 30

 

A2X-AVC-ELBOW

1/8 NPT street elbow, used between sensor DISS fittings and zone shut-off is included, but not attached.


NOTE:

Terminal strips are provided and installed, DISS demand checks and sensors are provided with alarm. The 1-½" zone shut-off will require an empty space above. Example: A box with ½", ¾" and 1-½" will require a 4 hole box not a 3 hole box. The 2" zone shut-off will be assembled in a 6-½" deep box and shall accommodate a maximum of up to 5 gases. The 2" zone shut-off shall be positioned on the bottom of the assembly. Refer to 2" zone indicator panel drawing above. The height measurements of the 6-½" zone shut-off box are the same as the 3-7/8" zone shut-off box. When comparing height measurements, consider the gap above the 2" zone shut-off.


Example: A box with 2", ¾" and a ½" would be in a 3 gang 6-½" box, which would be the same height as the 4 gang 3-7/8" box.

Languages

  • English
  • Français
  • Español