Ohmeda Compatible Wall Outlet
Ohmeda Compatible Wall Outlet

Wall Outlets

The Amico outlet continues to provide worry free and dependable service. Aesthetically pleasing in any patient room, this Ohmeda connection Amico gas outlet provides a full color fascia for easy gas identification during those “critical” moments. Amico’s outlets exceed flow rate requirements set by NFPA/CSA. All outlets are 100% cleaned and tested in order to ensure quality and are backed by our industry leading 5 year Warranty. We also have other configurations available to match your requirements.

DOWNLOADS:
BROCHUREORDERING GUIDEMANUALSSPEC SHEETS

Ohmeda Compatible Wall Outlet Specs

FilenameSizeType
ape_sp_qd_ohm_wall_outlt0.33MBPDF
ape_as_sp0.72MBPDF
DRAWINGS

Ohmeda Compatible Wall Outlet Drawings

FilenameSizeType
ape_dr_ohm_wall_outlt0.15MBDWG
ape_dr_ohm_wall_outlt0.08MBPDF

General Features

  • Flow rate exceeds the requirements of NFPA and CSA
  • Accepts only Ohmeda Diamond™ gas specific adaptors
  • 100% Pressure testing of each outlet and cleaned for medical gas service
  • Indexed to eliminate interchangeability of gas services
  • Up to 1" (25 mm) wall thickness adjustment
  • 360° Swivel Inlet Pipe for easy installation
  • Universal Rough-In Assembly to accept Quick Disconnects or DISS Front Adaptors (can be interchanged at any time)
  • Outlets are also available for M.R.I. use

Inch
[mm]

NOTE: Amico recommends that you have a blank space between outlets and slides. Maximum 3 outlets may be ganged together without additional support.

Dimensional drawings with specifications of the Ohmeda outlet

NOTE: For CSA/ISO, suction inlets are not supplied with a secondary check valve. A pressure plug is provided for testing purposes, rated at 150 psi (1,034 kPa).

 

Product Weight: 0.835 kg (1.84 lbs)

 

This drawing is also available on the spec sheet.

Model Numbers:

 

O-QDWAL-L-XXX ​  Standard Model 

for example: English NFPA, Oxygen = O-QDWAL-U-OXY
 

O-QDWALM-L-XXX ​​ M.R.I. Model

for example: English NFPA (M.R.I.), Oxygen = O-QDWALM-U-OXY​


 

The ”L” defines the Language:

U = English (NFPA) Oxy, Air, Vac and WAG only

E = English (CSA/ISO)

F = French (CSA/ISO)

SU = Spanish (NFPA)

S = Spanish (CSA/ISO)

 

The ”XXX” defines the Gas:

Oxygen = OXY

Medical Air = AIR

Nitrous Oxide = N2O

Carbon Dioxide = CO2

MedVac1 = VAC

Waste Anesthetic

Gas Disposal

(NFPA) = WAG

Anesthetic Gas

Scavenging

System' (CSA) = AGS

 

' Please see note above

Languages

  • English
  • Français
  • Español